Gmh95 gas furnace manual






















GMH95/GCH95/GCH9 GAS-FIRED WARM A IR FURNACE (Type FSP CATEGORY IV Direct or Non Direct Vent Air Furnace) RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. Installer: Affix all manuals adjacent to the unit. OFF, TURN OFF THE MANUAL GAS SHUTOFF VALVE EXTERNAL TO THE FURNACE BEFORE TURNING OFF THE . installer, service agency or the gas supplier warning should overheating occur or the gas supply fail to shut off, turn off the manual gas shutoff valve external to the furnace before turning off the electrical supply. warning keep this literature in a safe place for future reference. carbon monoxide poisoning hazard -bFile Size: 1MB. TECHNICAL MANUAL. GMH 40" 95% Gas Furnace • Refer to Service Manual RS for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Model numbers listed on page 3.


Air Conditioning Heat Pump AC with Gas Furnace · Individual Split System Units Home /, Product Manuals for Goodman GMH95 Technical Manual. Goodman GMHCX - Goodman GMHCX - OFF THE MANUAL GAS SHUTOFF VALVE EXTERNAL TO THE FURNACE BEFORE TURNING OFF THE ELECTRICAL SUPPLY. Download source to get this goodman furnace gmh95 installation manual. Here they BTU Name on front of furnace is the Dependable 97% AFUE Efficiency Unique and Dependable Heat Exchanger If you consider the heat exchanger an essential component of a gas Goodman GMVC8 Technical Manual. GMH95 40" 95% Gas Furnace • Refer to Service Manual RS for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Model numbers listed on page 3.


4 www.doorway.ru SS-GMH95 PRODUCT SPECIFICATIONS SPECIFICATIONS FOR GCH9 GCH9 BXA GCH9 BXA GCH9 CXA GCH9 CXA GCH9 DXA GCH9 DXA Heating Capacity Natural Gas Input¹ 46, 69, 69, 92, 92, , Goodman Gas Furnace: GMH95/ GCH Re: Flashing Code 4. Code 4 = Main limit switch (auto-reset) has opened its normally closed contacts, or the Blower Auxiliary Limit (manual-reset) has tripped. The control will operate the supply air blower and inducer while the open limit condition exists. PRODUCT DESIGN General Operation The GMH95 furnaces are equipped with an electronic igni- tion device used to light the burners and an induced draft blower to exhaust combustion products. An interlock switch prevents furnace operation if the blower door is not in place. Keep the blower access door in place except for inspection and maintenance.

0コメント

  • 1000 / 1000